Hypaject MK III Operating Instruction Manual Plastech Thermoset Tectonics Serial Number: KO24063 Unit 1, Delaware In
Hypaject MK III Instructions Issue 07: April 2001-04-23 10 3.0 Commissioning Notes. CAUTION Wear suitable protective clothing , approved eye pr
Hypaject MK III Instructions Issue 07: April 2001-04-23 11 4.0 Hypaject Operation 4.1 Resin Loading Procedure 1. Turn homogeniser pressure regula
Hypaject MK III Instructions Issue 07: April 2001-04-23 12 4.2 Procedure for set-up and use of High Temp Glass Faced Tool 1. Select the mould c
Hypaject MK III Instructions Issue 07: April 2001-04-23 13 9. Inject as per section 4.3 10. When the injection is complete, do not close the inje
Hypaject MK III Instructions Issue 07: April 2001-04-23 14 4.3 Injection Procedure CAUTION ! DO NOT OPEN THE LOAD VALVE WHEN THE HOMOGENISER IS U
Hypaject MK III Instructions Issue 07: April 2001-04-23 15 4.4 Hypaject Cleaning and Shut Down. Caution! Always ensure homogeniser pressure is zer
Hypaject MK III Instructions Issue 07: April 2001-04-23 16 10. With the flushing epoxy inside the homogeniser, turn off all temperature outputs and
Hypaject MK III Instructions Issue 07: April 2001-04-23 17 4. Place waste container under load pipe. Close inject valve. Ensure homogeniser pressu
Hypaject MK III Instructions Issue 07: April 2001-04-23 18 5.0 Maintenance CAUTION :- Wear suitable protective clothing , approved eye protect
Hypaject MK III Instructions Issue 07: April 2001-04-23 19 5.2 Resin load and resin injection valves To access the valve main diaphragm seals simpl
Hypaject MK III Instructions Issue 07: April 2001-04-23 2 Contents:- 1.0 Introduction. 2.0 Hypaject familiarisation and control functions
Hypaject MK III Instructions Issue 07: April 2001-04-23 20 6.0 APPENDIX A - Instructions for non Plastech equipment 6.1 OMRON E5CK series tempe
Hypaject MK III Instructions Issue 07: April 2001-04-23 3 1.0 Introduction. This manual covers the operation and maintenance of the Hypaject MK II
Hypaject MK III Instructions Issue 07: April 2001-04-23 4 2.2 Main Unit overview (example) The machine consists of the following components 1
Hypaject MK III Instructions Issue 07: April 2001-04-23 5 2.3 Control panel 2.3.2 Desktop Mounted Control Cabinet 1. Homogeniser Vacuum Gauge Me
Hypaject MK III Instructions Issue 07: April 2001-04-23 6 8. Mould Vacuum On/Off Switch (option) Switch down for ON, up for OFF 9. Mould Vacuum I
Hypaject MK III Instructions Issue 07: April 2001-04-23 7 20 Load Platform Up/Down Turn left to lower resin platform, right to raise resin platform
Hypaject MK III Instructions Issue 07: April 2001-04-23 8 180 degree operation. Enables selection of internal or external vacuum source. Turn towar
Hypaject MK III Instructions Issue 07: April 2001-04-23 9 CAUTION: - Do Not allow air supply to be switched off whilst Homogeniser remains press