MAGNUM VENUS PLASTECH
GRANITE COAT GUN REPAIR MANUAL REV: 3/29/2007
GRANIT COAT GUN
INTERNAL MIX
GMX-2000
Vista de página 0
1 2 3 4 5 6 ... 24 25

Resumo do Conteúdo

Página 1 - GMX-2000

MAGNUM VENUS PLASTECH GRANITE COAT GUN REPAIR MANUAL REV: 3/29/2007 GRANIT COAT GUN INTERNAL MIX GMX-2000

Página 2

10 PREPARATION AND PRIMING OF PREVIOUSLY USED (shut down) SYSTEM 1. Slowly open main air. 2. Material Pump: (be sure catalyst pump is disengag

Página 3

11 SHUT DOWN PROCEDURES FOR SPRAY EQUIPMENT 1. Trigger gun until pump shaft is in the full down position (at bottom of stroke position). 2. Eng

Página 4 - EQUIPMENT SAFETY

12 TESTING SPRAY PATTERN 1. Testing of your spray pattern should be performed away from original part. Use paper or cardboard to check the followin

Página 5

13 DISASSEMBLY OF GRANITE GUN GMX-2000 Caution: Always remove fluid pressures before working on the unit. WARNING: Be careful not to bend the catal

Página 6

14 Flush Valve Disassembly (5104-01-01) 1. Remove and discard the Flush Valve Split Seal (5104-21-1) from the Flush Valve Body (5104-24-1) 2. Remo

Página 7

15 ASSEMBLY OF GRANIT COAT GUN GMX-2000 Flush Valve Assembly (5104-01-01) See Drawing Flush Valve Assembly (5104-01-01) for reference 1. Install

Página 8 - WARNING

16 13. Install new O-Ring (O-S-012) on Catalyst Needle Housing (CPR-2003-02) and thread into Gun Block 14. Install new O-Ring (O-S-012) on Seal Ho

Página 9

17 Gun Adjustment and Start Up 1. Make sure trigger and trigger bar are no worn, loose or damaged before adjusting gun or needle guides. 2. Adjust

Página 10 - (shut down) SYSTEM

18 PARTS DRAWINGS: GMX-2000 GRANITE COAT GUN ASSEMBLY DRAWING GMX-2000-SK SEAL KIT – GRANITE COAT GUN 5104-03-01 INJECTOR ASSEMBLY 5104-01-

Página 15

22 TROUBLE SHOOTING: Catalyst Problems: 1. Catalyst leaking around Needle (inside Needle Housing CPR-2003-02)  Replace O-Ring (O-S-006) on Ne

Página 16

23 Resin Problems: 1. Resin leaking around Needle (inside Packing Nut MG-1022)  Tighten Packing Nut (MG-1022) a little  Replace Packing Seal (MA

Página 17 - Gun Adjustment and Start Up

24 1. Material leaking from around the mix chamber  Replace Mix Housing Seal (O-S-016) or Mix Housing Seal (5104-12-1)  Replace Catalyst Injecto

Página 18 - PARTS DRAWINGS:

25 Corporate HQ/Mfg. Manufacturing/Sales 5148 113th Ave. 1862 Ives Ave. Clearwater, FL 33760 USA Kent, WA 98032 USA Ph: (727) 573-295

Página 19

3 TABEL OF CONTENTS: 1. EQUIPMENT SAFTY 2. DISASSEMBLY OF GRANITE COAT GUN 3. ASSEMBLY OF GRANIT COAT GUN 4. PARTS DRAWINGS 5. TROUBLE SHOOT

Página 20

4 EQUIPMENT SAFETY Injection Hazard • DO NOT POINT THE GUN AT ANY PERSON • NEVER LOOK AT THE GUN FROM THE FRONT (NOZZLE END) • NEVER trigger an

Página 21

5 PUMPING SYSTEM SAFETY INSTRUCTIONS Use MVP replacement parts to assure compatible pressure rating. Read ALL warning and safety instructions carefu

Página 22 - TROUBLE SHOOTING:

6 pliable and to keep material drag-thru soft. Material drag-thru that is allowed to harden, will score the piston rod. This will create excessive

Página 23

7 Important safety information – The below potential hazards may cause an injury or loss of life HAZARD CAUSE SAFEGUARD Fire Solvent and coating

Página 24

8 WARNING Static Spark Can Cause explosion resulting severe injury or death. Ground pump and pumping system Injection Hazard Any material injected in

Página 25

9 PREPARATION AND PRIMING OF “NEW” SYSTEM 1. Be sure all air regulators are turned completely to the left, shutting off air to the components. 2